Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tede2.pucrs.br/tede2/handle/tede/6901
Registro completo de metadados
Campo DCValorIdioma
dc.creatorMoraes, Rodrigo Belagamba de-
dc.creator.Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4293345T9por
dc.contributor.advisor1Salton, Aurélio Tergolina-
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4177946D3por
dc.contributor.advisor-co1Baptista, Rafael Reimann-
dc.contributor.advisor-co1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4737443U7por
dc.date.accessioned2016-08-17T11:58:33Z-
dc.date.issued2016-04-26-
dc.identifier.urihttp://tede2.pucrs.br/tede2/handle/tede/6901-
dc.description.resumoEste trabalho propõe uma nova metodologia para detecção automática da ativação muscular em sinais de Eletromiografia (EMG). A qual utiliza a variância local do sinal para determinar os instantes de tempo que correspondem a eventos de ativação muscular. Duas técnicas existentes e consolidadas na literatura (Operador de Energia de Teager-Kaiser e Sample Entropy) foram implementadas com objetivo de realizar a detecção da ativação e viabilizar uma análise comparativa entre as diferentes metodologias. A avaliação dos resultados foram separadas em duas etapas: analise de performance e análise de convergência. Para realização da análise de performance foram estabelecidos critérios quantificáveis e objetivos: precisão, tolerância a ruídos e custo computacional. Foi desenvolvido também, um gerador de sinais de EMG sintéticos, cujos tempos de ativação muscular e a relação sinal ruído (SNR) eram previamente conhecidos. Considerando os critérios estabelecidos e o conjunto de dados analisados, a metodologia proposta demonstrou-se superior nos quesitos performance e tolerância a ruídos. A análise de convergência utilizou dados reais provenientes dez sujeitos, dos quais foram coletados sinais de oito músculos. Através desse conjunto de dados foi possível demonstrar a forte correlação entre os resultados obtidos pelos métodos analisados.por
dc.description.abstractThis study proposes a new methodology for automatic detection of muscle activation in electromyographic (EMG) signals. Which uses the local variance of EMG signal to determine the onset and offset times of muscle activation events. Were implemented two existing and consolidated methods (Teager-Kaiser Energy Operator and Sample Entropy) in order to carry the activation detection by another way and enable a comparative analysis of different methodologies. The evaluation of results was separated into two stages: performance analysis and convergence analysis. The performance analysis was established by quantifiable and objective parameters: accuracy, tolerance to noise and computational cost. It was developed also a generator of synthetic EMG signals whose muscle activation times and signal to noise ratio (SNR) were previously known. Considering the parameters established and the data analyzed, the proposed methodology demonstrated a better precision and tolerance to noise when compared to the others methods. The convergence analysis used the real EMG data from ten subjects, of which was collected signals from eight different muscles. Through this set of data, it was possible to demonstrate the high correlation between the results from the analyzed methods.eng
dc.description.provenanceSubmitted by Setor de Tratamento da Informação - BC/PUCRS ([email protected]) on 2016-08-17T11:58:33Z No. of bitstreams: 1 DIS_RODRIGO_BELAGAMBA_DE_MORAES_COMPLETO.pdf: 4117693 bytes, checksum: 8722e55214093bd6eca51d3ef5742ec8 (MD5)eng
dc.description.provenanceMade available in DSpace on 2016-08-17T11:58:33Z (GMT). No. of bitstreams: 1 DIS_RODRIGO_BELAGAMBA_DE_MORAES_COMPLETO.pdf: 4117693 bytes, checksum: 8722e55214093bd6eca51d3ef5742ec8 (MD5) Previous issue date: 2016-04-26eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede2.pucrs.br:80/tede2/retrieve/166015/DIS_RODRIGO_BELAGAMBA_DE_MORAES_COMPLETO.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentFaculdade de Engenhariapor
dc.publisher.countryBrasilpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétricapor
dc.rightsAcesso Abertopor
dc.subjectELETROMIOGRAFIApor
dc.subjectPROCESSAMENTO DE SINAISpor
dc.subjectTECNOLOGIA DA INFORMAÇÃOpor
dc.subjectENGENHARIA ELÉTRICApor
dc.subject.cnpqENGENHARIASpor
dc.titleMetodologia para detecção automática da ativação muscular em sinais eletromiográficospor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Engenharia Elétrica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DIS_RODRIGO_BELAGAMBA_DE_MORAES_COMPLETO.pdfTexto Completo4,02 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.