Export this record: EndNote BibTex

Please use this identifier to cite or link to this item: https://tede2.pucrs.br/tede2/handle/tede/1235
Full metadata record
DC FieldValueLanguage
dc.creatorPetri, Luciano Costa-
dc.creator.Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4745402Y3por
dc.contributor.advisor1Shinkai, Rosemary Sadami Arai-
dc.date.accessioned2015-04-14T13:30:31Z-
dc.date.available2014-01-22-
dc.date.issued2013-08-15-
dc.identifier.citationPETRI, Luciano Costa. Estudo prospectivo de falhas biomecânicas em próteses totais fixas implantossuportadas : série de casos. 2013. 83 f. Dissertação (Mestrado em Odontologia) - Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, 2013.por
dc.identifier.urihttp://tede2.pucrs.br/tede2/handle/tede/1235-
dc.description.resumoComplicações e falhas em próteses totais fixas implantossuportas (PTFI) podem estar relacionadas a fatores biológicos e mecânicos, tais como força máxima de mordida (FMM), desenho da infraestrutura metálica, espessura do revestimento estético e presença de bruxismo noturno. O objetivo deste estudo de série de casos foi descrever as falhas das PTFI em relação às características de espessura do revestimento estético, da força de mordida e da presença de bruxismo noturno. Foram acompanhados 17 pacientes que receberam PTFI durante um período de 6 a 12 meses. Os dados foram coletados através de exame físico, anamnese, medição de FMM e registro da distribuição de forças oclusais na arcada dentária em posições cêntrica e excêntricas (protrusão e lateralidades). A presença de bruxismo foi avaliada através de questionário, exame clínico e dispositivo BiteStrip®. Como resultado, foram observadas complicações em 4 pacientes, dos quais três indivíduos tiveram avulsão do dente da prótese e outro uma pequena fratura localizada adjacente ao orifício de acesso do parafuso em uma face dentária. Os achados sugerem que as falhas de avulsão de dente artificial podem ter ocorrido principalmente devido a falta de retenção interna proporcionada por pino da infraestrutura metálica. Já a fratura adjacente ao orifício de acesso do parafuso provavelmente ocorreu devido a uma excessiva abertura na resina do dente. Há necessidade de estudos subsequentes com ampliação da amostra e maior tempo de acompanhamento clínico para determinar os possíveis fatores de risco para falhas biomecânicas de PTFIs devido à sobrecarga oclusal e/ou desenho da infraestrutura.por
dc.description.abstractComplications and failures in implant supported fixed dentures (ISFD) can be related to several biological and mechanical factors, such as maximum bite force (MBF), design of the infrastructure, thickness of the aesthetic coating over metal framework and nocturnal bruxism. The aim of this case series study was to describe the failures of ISFD regarding the characteristics of aesthetic coating thickness, bite force and the presence of nocturnal bruxism. Seventeen patients who received ISFD were followed over a period of 6 to 12 months. Data were collected through anamnesis questionnaires, clinical examinations, MBF measurements and recording of the distribution of occlusal forces on the dental arch during centric and eccentric movements (protrusion and laterotrusion). The presence of bruxism was assessed by questionnaires, clinical examination and BiteStrip® device. Complications were observed in 4 patients, of which three individuals had avulsion of an artificial denture tooth while a small tooth fracture was located adjacent to the screw access hole in the other case. The findings suggest that failures caused by artificial tooth avulsion may have occurred mainly due to lack of internal retention provided by metal extensions of infrastructure. The fracture adjacent to the screw access hole was probably due to excessive opening on the resin tooth. Further studies with larger sample size and longer clinical follow-up are necessary to determine the possible risk factors for biomechanical failure of ISFD due to occlusal overload and / or design of the infrastructure.eng
dc.description.provenanceMade available in DSpace on 2015-04-14T13:30:31Z (GMT). No. of bitstreams: 1 453302.pdf: 2301270 bytes, checksum: cbc68a0ea07f8954655bd0c9592bed33 (MD5) Previous issue date: 2013-08-15eng
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://tede2.pucrs.br:80/tede2/retrieve/6885/453302.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentFaculdade de Odontologiapor
dc.publisher.countryBRpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectODONTOLOGIApor
dc.subjectPRÓTESE DENTÁRIApor
dc.subjectIMPLANTODONTIApor
dc.subjectBIOMECÂNICApor
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleEstudo prospectivo de falhas biomecânicas em próteses totais fixas implantossuportadas : série de casospor
dc.typeDissertaçãopor
Appears in Collections:Programa de Pós-Graduação em Odontologia

Files in This Item:
File Description SizeFormat 
453302.pdfTexto Completo2.25 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.