Export this record: EndNote BibTex

Please use this identifier to cite or link to this item: https://tede2.pucrs.br/tede2/handle/tede/1212
Full metadata record
DC FieldValueLanguage
dc.creatorBarbieri, Guilherme Machado-
dc.creator.Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4258342Y6por
dc.contributor.advisor1Burnett Junior, Luiz Henrique-
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4778680J0por
dc.date.accessioned2015-04-14T13:30:24Z-
dc.date.available2013-05-27-
dc.date.issued2013-01-17-
dc.identifier.citationBARBIERI, Guilherme Machado. Análise fotoelástica da influência da aplicação de carga no padrão de distribuição de tensões em implantes dentários. 2013. 67 f. Tese (Doutorado em Odontologia) - Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, 2013.por
dc.identifier.urihttp://tede2.pucrs.br/tede2/handle/tede/1212-
dc.description.resumoO objetivo deste estudo foi avaliar e comparar a distribuição de tensões de implantes utilizando a técnica da plataforma switching com os diâmetros convencionais, através do método da fotoelasticidade, em implantes do tipo hexágono externo e hexágono interno. Cinco modelos foram construídos com a resina fotoelástica KIT FLEXÍVEL G3 (POLIPOX Ind. E Com., São Paulo Brasil), com um implante unitário em cada um deles. Estes modelos foram MODELO A plataforma de 4.1mm HE/pilar de 4.1mm, MODELO B plataforma de 5.0mm HE/pilar de 4.1mm, MODELO C plataforma de 5.0mm HE/ pilar de 5.0mm, MODELO D plataforma de 4.5mm HI/pilar de 4.5mm e MODELO E plataforma de 4.5mm HI/pilar de 3.8mm. Uma carga axial de 100N foi aplicada em um polariscópio plano para a verificação da franjas isocromáticas. As imagens foram fotografadas com uma câmera digital CANON EOS DIGITAL REBEL XTI e visualizadas com o software especialmente desenvolvido para este trabalho. Os valores de tensão máxima cisalhante total para o implante HISW foi de 20,16KPa, HI 20,64KPa, HESW 21,84KPa, HE 21,70KPa e para o implante controle 20,74KPa. O implante de hexágono interno apresentou uma melhor distribuição de carga e menores valores de tensão com a utilização da técnica plataforma switching, sendo que nenhum sistema foi capaz de eliminar tensão em algum dos terços.por
dc.description.abstractThe aim of this study was to evaluate and compare stress distribution around implants using platform switching technique with conventional diameters, using the photoelasticity method in internal and external hex-type implants. Five models were fabricated using photoelastic resin kit FLEXIBLE G3 (POLIPOX Ind. E Com, Sao Paulo Brazil) with a single-body implant in each of them. These models were as follows: MODEL A - 4.1mm platform with 4.1mm external hex implant-abutment connection; MODEL B - 5.0mm platform with 4.1mm external hex implant-abutment connection; MODEL C - 5.0mm platform with 5.0-mm external hex implant-abutment connection; MODEL D - 4.5mm platform with 4.5mm internal hex implant-abutment connection; and MODEL E - 4.5mm platform 3.8mm internal hex implant-abutment connection. An axial load of 100N was applied in a plane polariscope to verify isochromatic fringes. The images were photographed with a digital camera CANON EOS DIGITAL REBEL XTI and viewed with software specially developed for this study. The values for total maximum shear stress for implant HISW was 20.16 kPa, HI 20.64 kPa, 21.84 kPa HESW, HE 21.70 kPa and 20.74 kPa for control implant. The internal hex implant showed better load distribution and lower stress values when the platform switching technique was used and no system was able to eliminate stress on some thirds.eng
dc.description.provenanceMade available in DSpace on 2015-04-14T13:30:24Z (GMT). No. of bitstreams: 1 448372.pdf: 1689966 bytes, checksum: 48a67133718d201e5dec9cece771f87c (MD5) Previous issue date: 2013-01-17eng
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://tede2.pucrs.br:80/tede2/retrieve/8190/448372.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentFaculdade de Odontologiapor
dc.publisher.countryBRpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectODONTOLOGIApor
dc.subjectDENTÍSTICApor
dc.subjectIMPLANTODONTIApor
dc.subjectFOTOELASTICIDADEpor
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleAnálise fotoelástica da influência da aplicação de carga no padrão de distribuição de tensões em implantes dentáriospor
dc.typeTesepor
Appears in Collections:Programa de Pós-Graduação em Odontologia

Files in This Item:
File Description SizeFormat 
448372.pdfTexto Completo1.65 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.