Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tede2.pucrs.br/tede2/handle/tede/1172
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBürgel, Marília Ostermann-
dc.creator.Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4268357P6por
dc.contributor.advisor1Pelisser, Fabiana Vieira Vier-
dc.contributor.advisor1Latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4709541Z3por
dc.date.accessioned2015-04-14T13:30:13Z-
dc.date.available2012-05-31-
dc.date.issued2012-03-28-
dc.identifier.citationBÜRGEL, Marília Ostermann. Avaliação da centralização do preparo do canal radicular e da fadiga do instrumento comparando três sistemas rotatórios de níquel-titânio. 2012. 53 f. Dissertação (Mestrado em Odontologia) - Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, 2012.por
dc.identifier.urihttp://tede2.pucrs.br/tede2/handle/tede/1172-
dc.description.resumoIntrodução: Este estudo in vitro avaliou a capacidade de centralização do preparo, bem como o desgaste distorção e a fratura de três tipos de instrumentos rotatórios de níquel-titânio (Ni-Ti) Wizard CD Plus (WP), Wizard Navigator (WN) e BioRace(BR). Metodologia: Foram utilizadas 90 raízes mésio-vestibulares (MV) de primeiros molares superiores (1ºs MS) e 10 conjuntos de cada tipo de instrumento rotatório. A sobreposição de imagens tomográficas de feixe cônico pré e pós-instrumentação avaliaram a capacidade de centralização do preparo, a 2,0, 4,0, 6,0 e 8,0mm do ápice. Os instrumentos foram avaliados em microscopia eletrônica de varredura (MEV), antes e após até o terceiro uso, na sua ponta e a 5mm desta. Os dados foram analisados pelo Teste de Kruskal-Wallis, complementado pelo Teste de Tukey (P<0.05). Resultados: Houve transporte do canal radicular em todos os grupos, não havendo diferença estatística entre os mesmos (P>0.05). Não houve fratura e distorção a 5mm da ponta nos instrumentos analisados. O grupo BR apresentou mais distorção na ponta do instrumento do que o grupo WP (P=0,011). Houve mais desgaste do instrumento no grupo WP do que no BR (P<0,001). Ocorreu aumento progressivo da distorção na ponta do instrumento e do desgaste em relação ao uso no grupo BR (distorção P=0,026 e desgaste P<0,001), assim como do desgaste no grupo WP (P<0,001). Conclusão: Nenhum dos sistemas rotatórios empregados foi capaz de proporcionar preparos centralizados e o uso progressivo dos instrumentos aumenta a ocorrência de distorção e desgastes em sua topografia.por
dc.description.abstractIntroduction: This in vitro study evaluated the capacity of centralization of the preparation, as well as the wear, distortion and fracture of three rotary nickel-titanium (Ni-Ti) systems Wizard CD Plus (WP), Wizard Navigator (WN) and BioRace(BR). Methodology: Were used 90 mesiobuccal roots (MV) of first upper molars (MS). The overlap of tomographic images before and after instrumentation was used to evaluate the transport of the preparation, at 2.0, 4.0, 6.0 and 8.0 mm from the apex. The instruments were observed by SEM before and after the third use, at its tip and at 5 mm of it. The data were analyzed by Kruskal-Wallis, complemented by Tukey test (P<0.05). Results: There was transport of the root canal in all groups, with no statistical difference between them (P> 0.05). There was no fracture and distortion at 5mm from the tip of the instruments. The group BR exhibited more distortion at the tip than the group WP (P = 0.011). There was more wear of the instrument in the group WP than in the BR (P <0.001). There was a progressive increase in distortion at the tip (P = 0.026) and of the wear (P <0.001) compared to the use in the group BR, as well as the wear in the group WP (P<0.001). Conclusion: None of the rotary systems employed was able to provide centralized preparation and the progressive use of the instruments did not favor the occurrence of fracture despite having increased the occurrence of distortion and weareng
dc.description.provenanceMade available in DSpace on 2015-04-14T13:30:13Z (GMT). No. of bitstreams: 1 438761.pdf: 1117817 bytes, checksum: 66a7869995a918890ef53d9067f6dc69 (MD5) Previous issue date: 2012-03-28eng
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://tede2.pucrs.br:80/tede2/retrieve/8107/438761.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentFaculdade de Odontologiapor
dc.publisher.countryBRpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectODONTOLOGIApor
dc.subjectENDODONTIApor
dc.subjectCANAL RADICULARpor
dc.subjectMICROSCOPIA ELETRÔNICApor
dc.subjectTOMOGRAFIApor
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleAvaliação da centralização do preparo do canal radicular e da fadiga do instrumento comparando três sistemas rotatórios de níquel-titâniopor
dc.typeDissertaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
438761.pdfTexto Completo1,09 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.