Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tede2.pucrs.br/tede2/handle/tede/10451
Registro completo de metadados
Campo DCValorIdioma
dc.creatorSilva, Carlos Augusto Gomes da-
dc.creator.Latteshttp://lattes.cnpq.br/1996280507622324por
dc.contributor.advisor1Grossi, Marcio Lima-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/4968642608747296por
dc.date.accessioned2022-09-13T16:45:14Z-
dc.date.issued2022-03-24-
dc.identifier.urihttps://tede2.pucrs.br/tede2/handle/tede/10451-
dc.description.resumoO objetivo do estudo foi mensurar à acurácia e precisão de modelos odontológicos impressos a partir de arquivos digitais em impressoras 3D com diferentes resinas e sistemas. A partir de um modelo dentário foram realizadas moldagens convencionais com Impregum Soft, e o escaneamento intraoral com o dispositivo Omnican AF. As moldagens resultaram em 10 modelos de gesso especial tipo IV, enquanto o arquivo digital originou 40 modelos de cada sistema: Esteriolitografia (SLA), Processamento digital da luz (DLP) e Visor de cristal líquido (LCD). Três variáveis de impressão foram avaliadas: Angulação do modelo (horizontal ou inclinada), tipo de resina (Três de referência e uma universal) e o sistema de impressão (SLA, DLP ou LCD), totalizando 12 combinações e um montante de 120 modelos. Todos as impressões foram realizadas com 50 μm no eixo Z. Foram aferidas a altura e a largura da coroa clínica dos dentes 16, 14, 12, 21 e 25; e da dimensão do arco através de pontos fixados nos caninos e primeiros molares. O coeficiente de correlação intraclasse (ICC) entre os avaliadores foi superior a 0,980. O RMS (root mean square) foi calculado em relação ao modelo mestre (acurácia) e em relação ao modelo de gesso (precisão). A comparação entre os diferentes grupos foi realizada pelo teste t de Student para amostras independentes (2 grupos) ou teste de Análise de variância (ANOVA) seguido do teste post hoc de Tukey (3 ou mais grupos). A correção de Bonferroni modificada por Finner foi utilizada para ajuste dos valores de p. O nível de significância de 5% foi determinado. Foram realizadas um total de 4800 medições. A variação da angulação do modelo sobre a plataforma não demonstrou para nenhuma das posições diferenças significativas com nenhum sistema ou resina (p>0,05). Na comparação geral dos sistemas houve maior acurácia e precisão no sistema DLP que nos sistemas SLA (p=0,002) e LCD (p=0,007), e nenhuma resina foi preponderante sobre as demais (p=0,08). Não se observou diferenças estatisticamente significativas entre as resinas de referência de cada sistema, e a resina universal Dental Cosmos (Yller) obteve melhor acurácia e precisão no sistema DLP, apresentando diferença estatisticamente significativa do SLA e LCD.por
dc.description.abstractThe aim of the study was to measure the accuracy and precision of dental models printed from digital files on 3D printers with different resins and systems. From a dental model, conventional impressions were made with Impregum Soft, and intraoral scanning with the Omnican AF device. The impressions resulted in 10 models of special type IV plaster, while the digital file generated 40 models of each system: Steriolithography (SLA), Digital Light Processing (DLP) and Liquid Crystal Display (LCD). Three printing variables were evaluated: model angle (horizontal or inclined), resin type (three reference and one universal) and the printing system (SLA, DLP or LCD), totaling 12 combinations and a total of 120 models. All impressions were made at 50 μm in the Z axis. The height and width of the clinical crown of teeth 16, 14, 12, 21 and 25 were measured; and the dimension of the arch through points fixed in the canines and first molars. The intraclass correlation coefficient (ICC) between evaluators was greater than 0.980. The RMS (root mean square) was calculated in relation to the master model (accuracy) and in relation to the plaster model (precision). The comparison between the different groups was performed using Student's t test for independent samples (2 groups) or Analysis of Variance (ANOVA) test followed by Tukey's post hoc test (3 or more groups). The Bonferroni correction modified by Finner was used to adjust the p-values. A 5% significance level was determined. A total of 4800 measurements were performed. The variation of the angulation of the model on the platform did not show significant differences for any of the positions with any system or resin (p>0.05). In the general comparison of the systems, there was greater accuracy and precision in the DLP system than in the SLA (p=0.002) and LCD systems (p=0.007), and no resin was predominant over the others (p=0.08). No statistically significant differences were observed between the reference resins of each system. Universal Dental Cosmos resin (Yller) obtained better accuracy and precision in the DLP system, showing a statistically significant difference for SLA and LCD.eng
dc.description.provenanceSubmitted by PPG Odontologia ([email protected]) on 2022-09-01T13:04:10Z No. of bitstreams: 1 CARLOS_AUGUSTO_GOMES_DA_SILVA_TES.pdf: 7164631 bytes, checksum: 038037755001fd08cb389dbaddd0d7c8 (MD5)eng
dc.description.provenanceApproved for entry into archive by Caroline Xavier ([email protected]) on 2022-09-13T16:34:50Z (GMT) No. of bitstreams: 1 CARLOS_AUGUSTO_GOMES_DA_SILVA_TES.pdf: 7164631 bytes, checksum: 038037755001fd08cb389dbaddd0d7c8 (MD5)eng
dc.description.provenanceMade available in DSpace on 2022-09-13T16:45:14Z (GMT). No. of bitstreams: 1 CARLOS_AUGUSTO_GOMES_DA_SILVA_TES.pdf: 7164631 bytes, checksum: 038037755001fd08cb389dbaddd0d7c8 (MD5) Previous issue date: 2022-03-24eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.description.sponsorshipConselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttps://tede2.pucrs.br/tede2/retrieve/185411/TES_CARLOS_AUGUSTO_GOMES_DA_SILVA_CONFIDENCIAL.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentEscola de Ciências Saúde e da Vidapor
dc.publisher.countryBrasilpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectImpressão 3Dpor
dc.subjectImpressão Digitalpor
dc.subjectManufatura Aditivapor
dc.subjectPrototipagem Rápidapor
dc.subjectImpressão DLPpor
dc.subjectSTLpor
dc.subjectLCDpor
dc.subject3D Printingeng
dc.subjectFingerprinteng
dc.subjectAdditive Manufacturingeng
dc.subjectRapid Prototypingeng
dc.subjectDLPeng
dc.subjectSTLeng
dc.subjectLCD Printingeng
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleAnálise de acurácia entre modelos odontológicos impressos com diferentes resinas e técnicas de prototipagem rápida e modelos convencionais em gessopor
dc.typeTesepor
dc.restricao.situacaoTrabalho será publicado como artigo ou livropor
dc.restricao.prazo60 mesespor
dc.restricao.dataliberacao13/09/2027por
Aparece nas coleções:Programa de Pós-Graduação em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TES_CARLOS_AUGUSTO_GOMES_DA_SILVA_CONFIDENCIAL.pdfCARLOS_AUGUSTO_GOMES_DA_SILVA_TES421,09 kBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.