Export this record: EndNote BibTex

Please use this identifier to cite or link to this item: https://tede2.pucrs.br/tede2/handle/tede/10001
Full metadata record
DC FieldValueLanguage
dc.creatorCavedini, Nícollas Gonçalves-
dc.creator.Latteshttp://lattes.cnpq.br/7248406497106855por
dc.contributor.advisor1Silva, Ana Maria Marques da-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/5375482124482980por
dc.contributor.advisor-co1Papaléo, Ricardo Meurer-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/1933730859000512por
dc.date.accessioned2021-12-07T19:33:01Z-
dc.date.issued2021-08-31-
dc.identifier.urihttp://tede2.pucrs.br/tede2/handle/tede/10001-
dc.description.resumoA dosimetria com géis poliméricos combinada com simulações de Monte Carlo, resulta em uma análise mais realística para controle de qualidade em radioterapia. O objetivo deste estudo é investigar o uso do gel dosimétrico MAGIC-f para medidas de dose devido à irradiação de fótons de alta energia de um acelerador linear de radioterapia através de estudos experimentais e de simulações de Monte Carlo. Dois lotes de gel MAGIC-f foram produzidos e colocados em tubos de ensaios. As irradiações foram realizadas no acelerador linear Varian IX, utilizando fótons com energia de 6 MV, tamanho de campo 20x20 cm² e distância fonte-objeto de 94 cm. Foram avaliados dois lotes do gel dosimétrico MAGIC-f, com doses planejadas de 0, 2, 4, 6, 8, 10, 20 e 40 Gy para o primeiro lote e 0, 2, 4, 6, 10, 12, 14 e 16 Gy para o segundo lote. O sistema Quimera, do Geant4, foi utilizado para as simulações de Monte Carlo, modelando o acelerador linear Varian IX com a abertura dos colimadores para diferentes tamanhos de campo. Todas as simulações foram realizadas em clusters do Laboratório de Alto Desempenho da PUCRS. Para a validação da simulação do acelerador linear, foram modeladas aquisições de porcentagem de dose profunda (PDP), utilizando um phantom cúbico de 48 x 48 x 40 cm³ preenchido com água. As imagens por ressonância magnética foram adquiridas com as sequências Multi Spin Eco (MSE) e Spin Eco (SE), utilizando 11 ecos. Para a sequência MSE, os valores de sensibilidade de dose obtidos foram de 0,27225 e 0,22717 Gy-1s-1 com TR = 3 s para o primeiro e segundo lote. Utilizando TR = 10 s, os valores de sensibilidade de dose foram de 0,28127 e 0,22978 Gy-1s-1 para o primeiro e segundo lote. Para a sequência SE, os valores de sensibilidade de dose foram de 0,41967 e 0,41158 Gy-1s-1, com TR = 3 s para o primeiro e segundo lote. Os valores experimentais de PDP foram utilizados para a validação da simulação, apresentando diferenças máximas de 2,9% (10 x 10 cm²), 2,3% (20 x 20 cm²), 1,9% (30 x 30 cm²) e 1,5% (40 x 40 cm²), em relação aos valores experimentais. Conclui-se que a sequência SE de MRI apresentam uma maior sensibilidade de dose em relação à MSE. A sensibilidade e a linearidade do gel MAGIC-f estão em acordo com estudos previamente publicados. Observa-se uma tendência linear da dose depositada nos tubos com o aumento do número de partículas simulado, sendo necessário o uso da técnica de splitter para a obtenção de maiores doses nos tubos.por
dc.description.abstractDosimetry with polymeric gels combined with Monte Carlo simulations results in an extremely reliable analysis for quality control in radiotherapy. This study aims to investigate the MAGIC - f dosimetric gel use for dose measurements due to high energy photon irradiation from a linear radiotherapy accelerator through experimental studies and Monte Carlo simulations. We produced two batches of MAGIC-f gel and placed into test tubes. The irradiations were carried out in a Varian IX linear accelerator, using photons with energy of 6 MeV, field size 20x20 cm², and source-object distance of 94 cm. Two batches of MAGIC - f dosimetric gel were evaluated, with planned doses of 0, 2, 4, 6, 8, 10, 20, and 40 Gy for the first batch and 0, 2, 4, 6, 10, 12, 14, and 16 Gy for the second batch. The Chimera system, from Geant4, was used for the Monte Carlo simulations, modeling the Varian IX linear accelerator with the opening of collimators for different field sizes. We performed all simulations in clusters at the PUCRS High-Performance Laboratory. To validate the linear accelerator simulation, we modeled deep dose percentage (PDP) acquisitions using a cubic phantom of 48 x 48 x 40 cm³ filled with water. Magnetic resonance images (MRI) were acquired with the Fast Spin Echo (MSE) and Spin Echo (SE) sequences, using 11 echoes. For the MSE sequence, the dose sensitivity values obtained were 0.27225 and 0.22717 Gy-1s-1 with TR = 3 s for the first and second batch. Using TR = 10 s, dose sensitivity values were 0.28127 and 0.22978 Gy-1s-1 for the first and second batch. For the SE sequence, dose sensitivity values were 0.41967 and 0.41158 Gy-1s-1, with TR = 3 s for the first and second batch. The experimental PDP values were used to validate the simulation, showing maximum differences of 2.9% (10 x 10 cm²), 2.3% (20 x 20 cm²), 1.9% (30 x 30 cm²) and 1.5% (40 x 40 cm²), in relation to the experimental values. Concluding, the MRI SE sequence has a greater dose sensitivity compared to MSE. The sensitivity and linearity of the MAGIC - f gel agree with previously published studies. There is a linear trend of the dose deposited in the tubes with the increase in the number of simulated particles, requiring the splitter technique to obtain higher doses.eng
dc.description.provenanceSubmitted by PPG Engenharia Elétrica ([email protected]) on 2021-11-30T17:24:29Z No. of bitstreams: 1 NÍCOLLAS GONÇALVES CAVEDINI_DIS.pdf: 8397365 bytes, checksum: d1ad6e274528dce35a678f82b3060f97 (MD5)eng
dc.description.provenanceApproved for entry into archive by Caroline Xavier ([email protected]) on 2021-12-07T19:28:55Z (GMT) No. of bitstreams: 1 NÍCOLLAS GONÇALVES CAVEDINI_DIS.pdf: 8397365 bytes, checksum: d1ad6e274528dce35a678f82b3060f97 (MD5)eng
dc.description.provenanceMade available in DSpace on 2021-12-07T19:33:01Z (GMT). No. of bitstreams: 1 NÍCOLLAS GONÇALVES CAVEDINI_DIS.pdf: 8397365 bytes, checksum: d1ad6e274528dce35a678f82b3060f97 (MD5) Previous issue date: 2021-08-31eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede2.pucrs.br:80/tede2/retrieve/182809/N%c3%8dCOLLAS%20GON%c3%87ALVES%20CAVEDINI_DIS.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentEscola Politécnicapor
dc.publisher.countryBrasilpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétricapor
dc.rightsAcesso Abertopor
dc.subjectGel Dosimétricopor
dc.subjectMAGIC-fpor
dc.subjectAcelerador Linearpor
dc.subjectSimulação de Monte Carlopor
dc.subjectGeant4por
dc.subjectDosimetric Geleng
dc.subjectMAGIC-feng
dc.subjectLinear Acceleratoreng
dc.subjectMonte Carlo Simulationeng
dc.subjectGeant4eng
dc.subject.cnpqENGENHARIASpor
dc.titleEstudo experimental e computacional de dosimetria utilizando o gel dosimétrico MAGIC-fpor
dc.typeDissertaçãopor
dc.restricao.situacaoTrabalho não apresenta restrição para publicaçãopor
Appears in Collections:Programa de Pós-Graduação em Engenharia Elétrica

Files in This Item:
File Description SizeFormat 
NÍCOLLAS GONÇALVES CAVEDINI_DIS.pdfNICOLLAS_GONCALVES_CAVEDINI_DIS8.2 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.