Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tede2.pucrs.br/tede2/handle/tede/8337
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBenetti, Tiago-
dc.creator.Latteshttp://lattes.cnpq.br/3451215312609297por
dc.contributor.advisor1Baptista, Rafael Reimann-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3050041150325700por
dc.date.accessioned2018-10-30T17:27:25Z-
dc.date.issued2018-08-31-
dc.identifier.urihttp://tede2.pucrs.br/tede2/handle/tede/8337-
dc.description.resumoO monitoramento da frequência cardíaca utilizando sinais de Fotopletismografia ou PPG (do inglês, Photopletismography) adquiridos do pulso de indivíduos tem se popularizado devido ao surgimento de inúmeros dispositivos wearable de baixo custo. No entanto, o monitoramento durante atividades físicas tem dificuldades em razão da influência de artefatos de movimento nos sinais de PPG. O objetivo deste trabalho é introduzir um novo algoritmo capaz de remover artefatos de movimento e estimar a frequência cardíaca de sinais de PPG de pulso. Os algoritmos do Mínimo Quadrado Médio Normalizado ou NLMS (do inglês, Normalized Least Mean Square) e de Mínimos Quadrados Recursivos ou RLS (do inglês, Recursive Least Squares) são propostos para uma estrutura de filtragem adaptativa que utiliza sinais de aceleração como referência para remover os artefatos de movimento. O algoritmo utiliza o Periodograma dos sinais filtrados para extrair suas frequências cardíacas, que serão utilizadas juntamente com um Índice de Qualidade do Sinal de PPG para alimentar a entrada de um Filtro de Kalman. Heurísticas específicas e o Índice de Qualidade colaboram para que filtro de Kalman forneça uma estimativa da frequência cardíaca com alta acurácia e robustez a incertezas de medição. O algoritmo foi validado a partir da frequência cardíaca obtida de sinais de Eletrocardiografia e o método proposto com o algoritmo RLS apresentou os melhores resultados com um erro médio absoluto de 1,54 batimentos por minuto (bpm) e desvio padrão de 0,62 bpm, registrados para 12 indivíduos realizando uma atividade de corrida em uma esteira com velocidades variadas. Os resultados tornam o desempenho do algoritmo comparável e até mesmo melhor que vários métodos desenvolvidos recentemente neste campo. Além disso, o algoritmo apresentou um custo computacional baixo e adequado ao intervalo de tempo em que a estimativa da frequência cardíaca é realizada. Dessa forma, espera-se que este algoritmo melhore a obtenção da frequência cardíaca em dispositivos wearable atualmente disponíveis.por
dc.description.abstractHeart rate monitoring using Photoplethysmography (PPG) signals acquired from the individuals pulse has become popular due to emergence of numerous low cost wearable devices. However, monitoring during physical activities has obstacles because of the influence of motion artifacts in PPG signals. The objective of this work is to introduce a new algorithm capable of removing motion artifacts and estimating heart rate from pulse PPG signals. Normalized Least Mean Square (NLMS) and Recursive Least Squares (RLS) algorithms are proposed for an adaptive filtering structure that uses acceleration signals as reference to remove motion artifacts. The algorithm uses the Periodogram of the filtered signals to extract their heart rates, which will be used together with a PPG Signal Quality Index to feed the input of a Kalman Filter. Specific heuristics and the Quality Index collaborate so that the Kalman filter provides a heart rate estimate with high accuracy and robustness to measurement uncertainties. The algorithm was validated from the heart rate obtained from Electrocardiography signals and the proposed method with the RLS algorithm presented the best results with an absolute mean error of 1.54 beats per minute (bpm) and standard deviation of 0.62 bpm, recorded for 12 individuals performing a running activity on a treadmill with varying speeds. The results make the performance of the algorithm comparable and even better than several recently developed methods in this field. In addition, the algorithm presented a low computational cost and suitable to the time interval in which the heart rate estimate is performed. Thus, it is expected that this algorithm will improve the obtaining of heart rate in currently available wearable devices.eng
dc.description.provenanceSubmitted by PPG Engenharia Elétrica ([email protected]) on 2018-10-29T13:30:23Z No. of bitstreams: 1 TIAGO BENETTI_DIS.pdf: 5038519 bytes, checksum: 95fa8d1b367b574eee27e772a55a9a49 (MD5)eng
dc.description.provenanceApproved for entry into archive by Caroline Xavier ([email protected]) on 2018-10-30T17:21:55Z (GMT) No. of bitstreams: 1 TIAGO BENETTI_DIS.pdf: 5038519 bytes, checksum: 95fa8d1b367b574eee27e772a55a9a49 (MD5)eng
dc.description.provenanceMade available in DSpace on 2018-10-30T17:27:25Z (GMT). No. of bitstreams: 1 TIAGO BENETTI_DIS.pdf: 5038519 bytes, checksum: 95fa8d1b367b574eee27e772a55a9a49 (MD5) Previous issue date: 2018-08-31eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://tede2.pucrs.br:80/tede2/retrieve/173476/TIAGO%20BENETTI_DIS.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentEscola Politécnicapor
dc.publisher.countryBrasilpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Elétricapor
dc.rightsAcesso Abertopor
dc.subjectAlgoritmo RLSpor
dc.subjectArtefatos de Movimentopor
dc.subjectFiltros Adaptativospor
dc.subjectFiltro de Kalmanpor
dc.subjectFrequência Cardíacapor
dc.subjectFotopletismografia (PPG)por
dc.subjectÍndice de Qualidade do Sinalpor
dc.subjectAdaptive Filterseng
dc.subjectHeart Rateeng
dc.subjectKalman Filtereng
dc.subjectMotion Artifactseng
dc.subjectPhotoplethysmography (PPG)eng
dc.subjectRLS Algorithmeng
dc.subjectSignal Quality Indexeng
dc.subject.cnpqENGENHARIASpor
dc.titleEstimativa robusta da frequência cardíaca a partir de sinais de fotopletismografia de pulsopor
dc.typeDissertaçãopor
dc.restricao.situacaoTrabalho não apresenta restrição para publicaçãopor
Aparece nas coleções:Programa de Pós-Graduação em Engenharia Elétrica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TIAGO BENETTI_DIS.pdfTIAGO_BENETTI_DIS4,92 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.