Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: https://tede2.pucrs.br/tede2/handle/tede/10455
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBregagnol, Raphaela Brambilla-
dc.creator.Latteshttp://lattes.cnpq.br/6740715409436147por
dc.contributor.advisor1Teixeira, Eduardo Rolim-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/6615000795050752por
dc.date.accessioned2022-09-13T18:41:19Z-
dc.date.issued2022-03-29-
dc.identifier.urihttps://tede2.pucrs.br/tede2/handle/tede/10455-
dc.description.resumoObjetivo: Avaliar a concordância entre mensuração linear com e sem sobreposição de imagens radiográficas para aferição da perda óssea peri-implantar, em função de arcada (maxila x mandíbula) e local do implante (intercalar x extremo livre). Metodologia: A amostra foi composta por 71 imagens radiográficas de 44 implantes unitários de 6mm de comprimento, instalados na região posterior de 19 pacientes. As radiografias periapicais padronizadas foram obtidas após a instalação da prótese (T0) e após 12 meses em função (T1). As imagens foram sobrepostas no software GIMP e as medidas lineares foram realizadas no software ImageJ. O nível ósseo foi obtido como a média mesial e distal. A perda óssea foi calculada subtraindo-se os valores em T1 de T0. Os dados foram analisados por coeficientes de correlação intraclasse (CCI). Resultados: A concordância geral entre os métodos foi de CCI = 0.88; estratificando por local do implante variou de CCI = 0.90 para extremo livre e CCI = 0.89 para intercalar. Quanto à arcada, os valores de CCI foram de 0.82 na maxila e 0.90 na mandíbula. Conclusão: A concordância entre as mensurações de perda óssea utilizando as duas técnicas foi alta, sugerindo que ambas as técnicas podem ser utilizadas em pesquisa de nível ósseo peri-implantar. Contudo, a sobreposição das imagens radiográficas adiciona mais uma etapa no processo de análise de imagens e, consequentemente, mais tempo operacional, o que deve ser também considerado ao escolher a técnica de mensuração.por
dc.description.abstractPurpose: To evaluate the agreement of linear measurements of peri-implant bone loss with and without superimposition of radiographic images, depending on the arch (maxilla x mandible) and implant site (intercalary x free end). Methodology: The study sample consisted of 71 radiographic images of 44 single implants of 6 mm length, located in the posterior region of 19 patients. Standardized radiographs was taken after implant loading (T0) and 12 months after 12 loading (T1). The images were superimposed on the GIMP software and the linear measurements were performed on the ImageJ software. The bone level measurements were calculated by the mesial and distal means. Bone loss was calculated by subtracting the T1 values from T0. Data were assessed using intraclass correlation coeficiente (ICC). Results: The overall agreement between the methods was CCI = 0.88; stratifying by implant site ranged from CCI = 0.90 for free end and CCI = 0.89 for intercalary. As for the arcade, the ICC values were 0.82 in the maxilla and 0.90 in the mandible. Conclusion: The agreement between the techniques was high, suggesting that both techniques can be used in periimplant bone level research. However, the overlay of radiographic images adds another step in the image analysis process and, consequently, more operating time, which must also be considered when choosing the measurement technique.eng
dc.description.provenanceSubmitted by PPG Odontologia ([email protected]) on 2022-09-02T12:15:18Z No. of bitstreams: 1 RAPHAELA_BRAMBILLA_BREGAGNOL_DIS.pdf: 1488246 bytes, checksum: ff7f80e685e7ce5c785a84536cf7d0c9 (MD5)eng
dc.description.provenanceApproved for entry into archive by Caroline Xavier ([email protected]) on 2022-09-13T18:37:11Z (GMT) No. of bitstreams: 1 RAPHAELA_BRAMBILLA_BREGAGNOL_DIS.pdf: 1488246 bytes, checksum: ff7f80e685e7ce5c785a84536cf7d0c9 (MD5)eng
dc.description.provenanceMade available in DSpace on 2022-09-13T18:41:19Z (GMT). No. of bitstreams: 1 RAPHAELA_BRAMBILLA_BREGAGNOL_DIS.pdf: 1488246 bytes, checksum: ff7f80e685e7ce5c785a84536cf7d0c9 (MD5) Previous issue date: 2022-03-29eng
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESpor
dc.formatapplication/pdf*
dc.thumbnail.urlhttps://tede2.pucrs.br/tede2/retrieve/185419/DIS_RAPHAELA_BRAMBILLA_BREGAGNOL_CONFIDENCIAL.pdf.jpg*
dc.languageporpor
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpor
dc.publisher.departmentEscola de Ciências Saúde e da Vidapor
dc.publisher.countryBrasilpor
dc.publisher.initialsPUCRSpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.subjectNível Ósseopor
dc.subjectPerda Ósseapor
dc.subjectImplantes Dentáriospor
dc.subjectRadiografias Intraoraispor
dc.subjectBone Leveleng
dc.subjectBone Losseng
dc.subjectIntraoral Radiographseng
dc.subjectDental Implantseng
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleMensuração linear de perda óssea periimplantar com e sem sobreposição de imagens radiográficas : estudo clínico metodológicopor
dc.typeDissertaçãopor
dc.restricao.situacaoTrabalho será publicado como artigo ou livropor
dc.restricao.prazo60 mesespor
dc.restricao.dataliberacao13/09/2027por
Aparece nas coleções:Programa de Pós-Graduação em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DIS_RAPHAELA_BRAMBILLA_BREGAGNOL_CONFIDENCIAL.pdfRAPHAELA_BRAMBILLA_BREGAGNOL_DIS409,8 kBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.